Hotel/Motel - Monitor Rooms

Description

This feature allows a hotel guest to use a guest room industry-standard telephone as a room monitor. The monitor provides a one-way audio call path from the guest room handset microphone to a listener device. The listener device may be an attendant console, line, or trunk. The listener device can only monitor an extension that has been previously activated as a room monitor.

You must program the appropriate COS options and feature access codes before the room monitor feature can be activated.

Conditions and Feature Interactions

General

Room Monitor Extension

Listener Device

Programming

  1. Class of Service Options form

To activate the room monitor feature, the following COS options must be enabled

  1. Feature Access Codes form

Assign values to the following feature access codes:

 

Operation

Activating a Room Monitor Extension

  1. Ensure that the appropriate COS options and feature access codes have been enabled.

  2. Put the room monitor extension off-hook.

  3. Enter the Hotel/Motel Room Monitor Setup feature access code.

  4. When you have successfully activated the room monitor feature, leave the room monitor extension off-hook.

Successful activation: You will hear a confirmation tone (same as paging tone) followed by silence when the feature is activated.

Unsuccessful activation: You will hear reorder tone if the feature is not activated.

Disconnecting the Room Monitor Extension

To disconnect the room monitor extension:

Activating a Telephone Set Listener Device

  1. Ensure that the appropriate COS options and feature access codes have been enabled.

  2. Ensure that the room monitor extension has been activated.

  3. Enter the Hotel/Motel Room Monitor Listen feature access code.

  4. Dial the room monitor extension number.

    Successful activation
    :

  5. You will hear a confirmation tone (same as paging tone) followed by the monitored audio from the room monitor when the feature is activated.

  6. IP display telephones: "Monitor" will be displayed when the monitor feature is activated. The "Hang-Up/New Call" prompt (where applicable) will be displayed while the listener device is connected to the room monitor extension.
     

Unsuccessful activation:

NOTE: If the listener device is a display set calling across DPNSS/MSDN from another system, the system responses will be the same as those indicated above with the following exceptions,

 

Disconnecting the Telephone Set Listener Device

To disconnect the listener device:

Activating an IP Console Application Listener Device

You can only monitor a room from an idle console.

  1. Select Guest Services from the Tools menu.

  2. Select Room Monitor.

  3. Dial the room number.

  4. Listen for three short beeps followed by audio from the room.

  5. If room monitoring is not activated on the room telephone, you will hear reorder tone or a beep.

  6. If you see "Monitor Busy", then another extension is already monitoring the room.

  7. If you see "Class Restricted" or "Access Denied", then the room cannot be monitored because of restrictions on the console or the room telephone.

To disconnect the console from the room:

Activating a 5540 IP Console Listener Device

  1. Enter Guest service mode.

  2. Press the MORE softkey.

  3. Type the room extension number.

  4. Press the Monitor Room softkey.

  5. Listen for three short beeps followed by audio from the room.

  6. If room monitoring is not activated on the room telephone, the display will show " FTr Disald."

  7. If another extension is already monitoring the room, the display will show " MntrBusy."

To disconnect the console from the room: